Wall Panel Mount Type Sensor
Wall Panel Mount Type Sensor
Product Code : 19
Price And Quantity
- Minimum Order Quantity
- 1 Piece
- Price
- Depends on Product INR
Wall Panel Mount Type is designed in compact and durable design to ensure maximum robustness. This is provided with a vast range of input power sources to serve varied requirements of industries. Combination of different units ensures proper and precise detection of gases. It comes in sturdy structure to resist rust, abrasion and wear. In addition to this, it is available in customized specifications and dimensions to meet various needs of the patrons.
Features:
- Compact design
- Standard cases for 3/6/9/12/15 points are available
- Wide variety of input power sources
- Can be equipped with a Zener barrier
- Combination of the V3 series (or V/V2 series) units allows detection of and alarm for various gases
Technical Specifications:
TD P { margin-bottom: 0cm; }P { margin-bottom: 0.21cm; }A:link { color: rgb(0, 0, 255); }
Model | UV-810 |
Points of Indicator | Up to 15 point (line up: 3 point type,/6 point type /9 point type /12 point type /15 point type) |
Alarm Accuracy | As per gas detector: Combustible gas: within 25% of alarm value under an identical condition Toxic gas: within 30% of alarm value under an identical condition |
Alarm Indication Alarm Sound | Indicator unit Alarm lamp: blnks on alarm, lights up by reset, latching (or non-latching) Alarm unit Trouble lamp: red lamp lights up (1st stage, 2nd stage) when at least one indicator unit is activated yellow lamp lights up when at least one indicator unit cause a malfunction |
External Output | Terminal for collective alarm 2nd alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance) 1st alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance) Buzzer contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance) Trouble contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance) *Collective alarm contacts of 1st alarm and 2nd alarm can be changed to 1b contact (need to specify) Terminal for individual alarm 2nd alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance) 1st alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance) Analog output Gas concentration analog output signal: 4-20 mA, selectable from 1-5 V (need to specify) |
Power Source | AC specification: 100-240 VAC ±10% DC specification: 24 VDC ±10% (need to specify) |
Power Consumption | AC input: 100-240 V, Pump power supply: 24 VDC Power consumption (VA) = (V3 x points of indicator + VAS) x 1.25 (SW power loss) DC input (24 V ±10%), Pump power supply: 24 VDC Power consumption (W) = (V3 x points of indicator + VAS) **V3 includes power consumption of gas detector |
Environment of usage | Operating Temperature:-10 to +40 °C (excluding rapid temperature change) Operating Humidity: 10 to 90 %RH (excluding rapid temperature change, non-condensing) |