Our vast industry experience enable us manufacture, export and supply a wide assortment of Lpg Gas Leakage Sensor. Our dedicated professionals make use of pioneering technology and superior grade basic material to manufacture this leakage sensor with utmost efficiency. Provided sensor is well suited for sensing the leakage of lpg gas at several industries. Also, this Lpg Gas Leakage Sensor can be bought in numerous technical specifications.
Features:
Item | Model | NV-500 | ||
Detection Principle | Catalytic combustion | |||
Gas Detected | LPG | |||
Detection Points per Unit | Monitors 2 points per unit | |||
Detection Range | O-100% LEL (isobutane) | |||
Concentration Indicator Alarm Set Value Indication Backlight Peak Hold Function (on alarm) | LCD bar-graph meter (53 dots x 2 lines) Direct reading scale Yes Holds a peak value on alarm, which is canceled by the Reset | |||
Alarm Set Value(default value)/Change of the Set Value | 24% LEL | |||
Alarm Accuracy | +/-25% of Alarm Set Value (under identical conditions) | |||
Response Time | 30s or less at 160% concentration of an Alarm Set Value (excluding sampling delay for extractive type) | |||
Alarm Indication | Individual alarm lamp latching | On alarm: Flashes red, lights up after the Buzzer Stop Complete lock (Turn off by the Reset after the level declined) | ||
Alarm Sound | Standard operation | On alarm: Intermittent buzzer, stops after the Buzzer Stop | ||
Voice alarm | On alarm: Intermittent buzzer | |||
External Alarm Output | Individual alarm contact | 1a no-voltage (Contact capacity: 2A@100 V AC) | ||
Individual voltage output | 0-6-12V DC (20mA or less) | |||
Collective alarm contact | 1c no-voltage (Contact capacity: 2A@100V AC) | |||
Centralized monitor panel output | 0-6-12V DC (20mA or less) | |||
External buzzer contact | 1a no-voltage (Contact capacity: 2A@100V AC) | |||
External buzzer voltage output | Intermittent voltage signal (12V DC, 10mA or less) | |||
Alarm Delay | Selectable by a DIP switch (10s constant) | |||
Main Power Source | 85-264V AC | |||
Power Consumption | When using KD-14 | Diffusion type (15+3.5n)VA | ||
When using PD-14 | Extractive type (15+7.5n)VA | |||
Backup power source (only on models with a built-in backup a power supply) | Battery type | Sealed lead acid battery | ||
Overdischarge prevention function | Yes | |||
Battery life check function | Yes | |||
Battery voltage indication | 2-digit LED | |||
Exterior Color | Munsell 2.5 PB 7.0/1.0 |