Wall Panel Mount Type Sensor

Wall Panel Mount Type Sensor

Product Details:

X

Wall Panel Mount Type Sensor Price And Quantity

  • 1 Piece
  • INR

Wall Panel Mount Type Sensor Trade Information

  • Per Week
  • 2-10 Week

Product Description

Wall Panel Mount Type is designed in compact and durable design to ensure maximum robustness. This is provided with a vast range of input power sources to serve varied requirements of industries. Combination of different units ensures proper and precise detection of gases. It comes in sturdy structure to resist rust, abrasion and wear. In addition to this, it is available in customized specifications and dimensions to meet various needs of the patrons.

Features:

  • Compact design
  • Standard cases for 3/6/9/12/15 points are available
  • Wide variety of input power sources
  • Can be equipped with a Zener barrier
  • Combination of the V3 series (or V/V2 series) units allows detection of and alarm for various gases

Technical Specifications:

Model

UV-810

Points of Indicator

Up to 15 point
(line up: 3 point type,/6 point type /9 point type /12 point type /15 point type)

Alarm Accuracy

As per gas detector:
Combustible gas: within 25% of alarm value under an identical condition
Toxic gas: within 30% of alarm value under an identical condition

Alarm Indication
Alarm Sound

Indicator unit
Alarm lamp: blnks on alarm, lights up by reset, latching (or non-latching)
Alarm unit
Trouble lamp:
red lamp lights up (1st stage, 2nd stage) when at least one indicator unit is activated
yellow lamp lights up when at least one indicator unit cause a malfunction

External Output

Terminal for collective alarm
2nd alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
1st alarm contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
Buzzer contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
Trouble contact: 1a non-voltage (STD) (100 VAC, 1A. 24 VDC, 1A load resistance)
*Collective alarm contacts of 1st alarm and 2nd alarm can be changed to 1b contact (need to specify)
Terminal for individual alarm
2nd alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
1st alarm contact: 1a non-voltage (STD) (250 VAC, 2A. 24 VDC, 2A load resistance)
Analog output
Gas concentration analog output signal: 4-20 mA, selectable from 1-5 V (need to specify)

Power Source

AC specification: 100-240 VAC ±10%
DC specification: 24 VDC ±10% (need to specify)

Power Consumption

AC input: 100-240 V, Pump power supply: 24 VDC
Power consumption (VA) = (V3 x points of indicator + VAS) x 1.25 (SW power loss)
DC input (24 V ±10%), Pump power supply: 24 VDC
Power consumption (W) = (V3 x points of indicator + VAS)
**V3 includes power consumption of gas detector

Environment of usage

Operating Temperature:-10 to +40 °C (excluding rapid temperature change)
Operating
Humidity: 10 to 90 %RH (excluding rapid temperature change, non-condensing)

Enter Buying Requirement Details
Email Id
Mobile number